Got my dipole onto the 12m band while investigating power limit issues for 10m and I might just stay here for a while. :3
Still need to figure out the power issue, though. Using the braid of LL240 coax as the conductor for the loading coil worked a charm. When I was using magnet wire for the same, the turns got hot, but now I don't notice any heat. I also have stacked T200-2 cores, which don't appear to be warming up like the earlier single T200-2 core. At this point, it seems like the matching autotransformer (a single FT240-43) might be the issue, as it is still getting pretty warm. Will most likely rebuild it with stacked cores. 🤔